Carina Series 3

About PRODUCT

Stylish design with advanced heat dissipating system

* Uniform and glare-free light distribution

* High luminous efficiency and long lifetime in order to reduce energy costs

* Standard power supply capable of precise flow control, high power factor and low harmonic distortion

* Constant power consumption and light output in a wide range of supply voltage (180-265VAC)

* Power supply with over voltage transient protection

* Wide ambient temperature range and possibility to operate in different climates

* High ingress protection and good resistance to corrosion and mechanical stress

* Equipped with impact resistant window film

* No ultraviolet and infrared radiation

* Producible with various color temperatures 

* High level of Ingress Protection (IP)

* Adjustable bracket holder for -15 to +15 degrees angles


 


# Color also available in 3000 (°K) ,4000 (°K) and 6500 (°K)

Lighting project planning legend

H: pole height

W: light beam length

S: spacing between poles

H:6m W:6m
Class Power Spacing(S) T1 %
C1 125W 27m
C1 150W 28m
C0 150W 19m
H:6m W:7m
Class Power Spacing(S) T1 %
C1 125W 25m
C0 150W 18m
C1 150W 27m
H:6m W:8m
Class Power Spacing(S) T1 %
C0 150W 17m
C1 150W 25m
H:6m W:9m
Class Power Spacing(S) T1 %
C0 150W 16m
H:6.5m W:8m
Class Power Spacing(S) T1 %
C1 125W 23m
H:7m W:9m
Class Power Spacing(S) T1 %
C1 150W 25m
H:7.5m W:6m
Class Power Spacing(S) T1 %
M1 125W 21m 10
C2 125W 35m
H:7.5m W:7m
Class Power Spacing(S) T1 %
M1 125W 20m 10
C2 125W 33m
H:7.5m W:8m
Class Power Spacing(S) T1 %
C2 125W 32m
H:7.5m W:9m
Class Power Spacing(S) T1 %
C1 125W 20m
H:8m W:6m
Class Power Spacing(S) T1 %
C2 150W 36m
H:8m W:7m
Class Power Spacing(S) T1 %
M1 150W 22m 10
C2 150W 37m
H:8m W:8m
Class Power Spacing(S) T1 %
M1 125W 18m 9
M1 150W 21m 10
C2 150W 36m
H:8m W:9m
Class Power Spacing(S) T1 %
C2 125W 29m
C2 150W 35m
H:8.5m W:6m
Class Power Spacing(S) T1 %
M1 150W 23m 9
M2 150W 29m 10
H:8.5m W:7m
Class Power Spacing(S) T1 %
M2 125W 24m 9
C3 125W 40m
H:8.5m W:8m
Class Power Spacing(S) T1 %
M2 125W 23m 9
M3 125W 35m 13
C3 125W 39m
H:8.5m W:9m
Class Power Spacing(S) T1 %
M3 125W 32m 13
C3 125W 36m
M1 150W 19m 10
H:9m W:6m
Class Power Spacing(S) T1 %
M2 125W 25m 9
M3 125W 37m 8
C3 150W 40m
H:9m W:7m
Class Power Spacing(S) T1 %
M3 125W 36m 11
M2 150W 28m 10
H:9m W:8m
Class Power Spacing(S) T1 %
M2 150W 26m 9
H:9m W:9m
Class Power Spacing(S) T1 %
M2 125W 21m 8
M2 150W 25m 10
H:10m W:6m
Class Power Spacing(S) T1 %
M3 150W 41m 10

The lighting classes include:

– Motorized traffic roads for medium to high vehicular speed (50 to 150 km/hour), called M,

– Roads or stretches of roads with conflict areas called C (relevant areas where motorized traffic streams intersect each other or overlap areas frequented by other user types, where the traffic is made critical by the presence of elements of discontinuity, which queues, shops, intersections, etc.);

– Streets, sidewalks, lanes intended for pedestrians or cyclists, isolated or adjacent to roadway traffic, called P.